8.4.2. Check of a starter at the stand

 Working capacity check
Test in the mode of full braking
POSSIBLE MALFUNCTIONS OF THE STARTER, THEIR REASON AND METHODS OF ELIMINATION
Test on the idling mode
Check of the traction relay






Fig. 8-16. The scheme of connections for check of a starter at the stand: 1 — the rechargeable battery; 2 — the ampermeter with the shunt on 1000 A; 3 — the switch; 4 — a rheostat; 5 — the voltmeter with a scale limit not less than 15 V; 6 — a starter

If there is a doubt in overall performance of a starter, it is necessary to check it at the stand. The electric circuit of connections for check of a starter at the stand is shown in fig. 8-16. Connecting wires to a current source, the ampermeter and a contact bolt of the traction relay of a starter have to have section not less than 16 mm2.
Starter temperature when checking has to be (25±5) °C, and brushes — are ground well in to a collector.